3.1.1.11. Product comparison table¶
Basic |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
Processor |
DUAL CORE ARM CORTEX A9 |
DUAL CORE ARM CORTEX A9 |
DUAL CORE ARM CORTEX A9 |
DUAL CORE ARM CORTEX A9 |
DUAL CORE ARM CORTEX A9 |
DUAL CORE ARM CORTEX A9 |
FPGA |
FPGA Xilinx Zynq 7010 SOC |
FPGA Xilinx Zynq 7010 SOC |
FPGA Xilinx Zynq 7020 SOC |
FPGA Xilinx Zynq 7020 SOC |
FPGA Xilinx Zynq 7020 SOC |
FPGA Xilinx Zynq 7020 SOC |
RAM |
256 MB (2 Gb) |
512 MB (4 Gb) |
512 MB (4 Gb) |
512 MB (4 Gb) |
512 MB (4 Gb) |
1 GB (8 Gb) |
System memory |
Micro SD up to 32 GB |
Micro SD up to 32 GB |
Micro SD up to 32 GB |
Micro SD up to 32 GB |
Micro SD up to 32 GB |
Micro SD up to 32 GB |
Console connection |
USB to serial converter required |
Micro USB |
Micro USB |
Micro USB |
Micro USB |
USB-C |
Power connector |
Micro USB |
Micro USB |
Micro USB |
Micro USB |
Micro USB |
Power Jack |
Power consumption |
5 V, 1, 5 A max |
5 V, 2 A max |
5 V, 2 A max |
5 V, 2 A max |
5 V, 2 A max |
24 V, 0.5 A max |
Connectivity |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
Ethernet |
1 Gbit |
1 Gbit |
1 Gbit |
1 Gbit |
1 Gbit |
1 Gbit |
USB |
USB 2.0 |
USB 2.0 |
USB 2.0 |
USB 2.0 |
USB 2.0 |
2 x USB 2.0 |
WIFI |
requires WIFI dongle |
requires WIFI dongle |
requires WIFI dongle |
requires WIFI dongle |
requires WIFI dongle |
requires WIFI dongle |
RF inputs |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
RF input channels |
2 |
2 |
2 |
4 |
2 |
2 |
Sample rate |
125 MS/s |
125 MS/s |
125 MS/s |
125 MS/s |
122.88 MS/s |
250 MS/s |
ADC resolution |
10 bit |
14 bit |
14 bit |
14 bit |
16 bit |
12 bit |
Input impedance |
1 MOhm / 10 pF |
1 MOhm / 10 pF |
1 MOhm / 10 pF |
1 MOhm / 10 pF |
50 Ohm |
1 MOhm |
Full scale voltage range |
±1 V (LV) and ±20 V (HV) |
±1 V (LV) and ±20 V (HV) |
±1 V (LV) and ±20 V (HV) |
±1 V (LV) and ±20 V (HV) |
0.5 Vpp/-2 dBm |
+-1 V/+-20 V (software selectable) |
Input coupling |
DC |
DC |
DC |
DC |
AC |
AC / DC (software selectable) |
Absolute max. Input voltage range |
30 V |
30 V |
30 V |
30 V |
DC max 50 V (AC-coupled) 1 Vpp for RF |
30 V |
Input ESD protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Overload protection |
Protection diodes |
Protection diodes |
Protection diodes |
Protection diodes |
DC voltage protection |
Protection diodes |
Bandwidth |
DC - 50 MHz |
DC - 60 MHz |
DC - 60 MHz |
DC - 60 MHz |
300 kHz - 550 MHz |
DC - 60 MHz |
RF outputs |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
RF output channels |
2 |
2 |
2 |
N/A |
2 |
2 |
Sample rate |
125 MS/s |
125 MS/s |
125 MS/s |
N/A |
122.88 MS/s |
250 MS/s |
DAC resolution |
10 bit |
14 bit |
14 bit |
N/A |
14 bit |
14 bit |
Load impedance |
50 Ohm |
50 Ohm |
50 Ohm |
N/A |
50 Ohm |
50 Ohm |
Voltage range |
±1 V |
±1 V |
±1 V |
N/A |
0.5 Vpp/ -2 dBm (50 Ohm load) |
+-2 V / +-10 V (Hi-Z load) (software selectable) |
Short circut protection |
Yes |
Yes |
Yes |
N/A |
N/A, RF transformer & AC-coupled |
Yes |
Connector type |
SMA |
SMA |
SMA |
N/A |
SMA |
BNC |
Output slew rate |
2 V / 10 ns |
2 V / 10 ns |
2 V / 10 ns |
N/A |
N/A |
10 V / 17 ns |
Bandwidth |
DC - 50 MHz |
DC - 50 MHz |
DC - 50 MHz |
N/A |
300 kHz - 60 MHz |
DC - 60 MHz |
Extension connector |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
Digital IOs |
16 |
16 |
16 |
20 |
16 |
16 |
Analog inputs |
4 |
4 |
4 |
4 |
4 |
4 |
Analog inputs voltage range |
0-3.5 V |
0-3.5 V |
0-3.5 V |
0-3.5 V |
0-3.5 V |
0-3.5 V |
Sample rate |
100 kS/s |
100 kS/s |
100 kS/s |
100 kS/s |
100 kS/s |
100 kS/s |
Resolution |
12 bit |
12 bit |
12 bit |
12 bit |
12 bit |
12 bit |
Analog outputs |
4 |
4 |
4 |
4 |
4 |
4 |
Analog outputs voltage range |
0-1.8 V |
0-1.8 V |
0-1.8 V |
0-1.8 V |
0-1.8 V |
0-1.8 V |
Communication interfaces |
I2C, SPI, UART |
I2C, SPI, UART |
I2C, SPI, UART |
I2C, SPI, UART |
I2C, SPI, UART |
I2C, SPI, UART, USB |
Available voltages |
+5 V, +3.3 V, -4 V |
+5 V, +3.3 V, -4 V |
+5 V, +3.3 V, -4 V |
+5 V, +3.3 V, -4 V |
+5 V, +3.3 V, -4 V |
+5 V, +3.3 V, -4 V |
external ADC clock |
N/A |
yes |
yes |
yes |
yes |
yes |
Synchronisation |
||||||
---|---|---|---|---|---|---|
STEMlab 125-10 |
STEMlab 125-14 |
STEMlab 125-14-Z7020-LN |
STEMlab 125-14 4-Input |
SDRlab 122-16 |
SIGNALlab 250-12 |
|
Trigger input |
Through extension connector |
Through extension connector |
Through extension connector |
Through extension connector |
Through extension connector |
Through BNC connector |
Daisy chain connection |
N/A |
Over SATA connection |
Over SATA connection |
Over SATA connection |
Over SATA connection |
Over SATA connection |
Ref. clock input |
N/A |
N/A |
N/A |
N/A |
N/A |
Through SMA connector |
Note
Red Pitaya devices:
should be operated at normal conditions with ambient temperatures not exceeding 30°C (86°F) and should not be covered.
are intended for indoor use at a maximum altitude of 2000 m, pollution degree 2, and relative humidity less than 90%.
intended for use with low-voltage energy sources and signals; it should not be used in any direct connection with voltages above 30 volts.
Warning
All inputs and outputs available through SMA and BNC connectors share a common ground connected to the power supply ground.
Warning
Power supply precautions:
STEMlab 125-14, STEMlab 125-14-Z7020, STEMlab 125-14 4-Input, STEMlab 125-10, SDRlab 122-16 shall only be powered by an isolated external power supply providing 5 volts direct current, and a maximum current of 2 Amperes. The KA23-0502000DES model is recommended. Any other external power supply used with Red Pitaya must comply with relevant regulations and standards applicable in the country of use.
SIGNALlab 250-12 shall only be powered by an original KA2401A 24V/1A isolated power supply or through RJ45 ethernet connector (PoE version only).